Technical Blog

How to Choose Photovoltaic Cable for a Solar Farm

Select PV cable by voltage rating (1.5 kV DC), temperature range, UV/ozone resistance and double insulation — not by price alone. A practical specification guide for EPCs and solar farm buyers.

6 min readLIAONING CHUANGSHENG

Choose photovoltaic cable rated for 1.5 kV DC, a conductor temperature range of about −40 °C to +90 °C (125 °C short-circuit), UV- and ozone-resistant cross-linked insulation and a twin-wall sheath. For a typical solar farm this means a 4 mm² or 6 mm² copper DC cable that carries the string current with margin; final sizing depends on string current, run length and allowable voltage drop.

Why solar cable is not ordinary cable

PV arrays operate outdoors for 25–30 years, often at rooftop or desert temperatures, under constant UV exposure and daily thermal cycling. A general-purpose PVC building wire is not rated for continuous outdoor UV exposure or for 1.5 kV DC. Photovoltaic cable uses electron-beam cross-linked insulation and sheath compounds specifically formulated to resist UV, ozone and temperature extremes.

The four specifications that matter

1) Rated voltage: 1.5 kV DC (1500 V) is now standard for utility-scale strings; 1.0 kV DC suits smaller residential systems. 2) Temperature: look for −40 °C to +90 °C operating, with a 125 °C short-circuit rating. 3) Weather resistance: the sheath must carry a UV/ozone resistance rating and be suitable for outdoor use. 4) Construction: a double-insulated, tinned copper, flexible conductor improves durability and termination reliability.

Sizing: 4 mm² vs 6 mm²

Both sizes are common on DC strings. 4 mm² is typically sufficient for strings with moderate current and short runs; 6 mm² reduces voltage drop on longer home runs and carries more current with less heating. Size the conductor from the module's short-circuit current (Isc), apply the design factor required by the installation standard, then check voltage drop over the total circuit length. Oversizing slightly is cheaper than re-pulling cable after commissioning.

Frequently asked questions

Can I use ordinary building wire for solar panels?

No. Building wire is not rated for continuous outdoor UV exposure or for 1.5 kV DC. Use cable specifically rated for photovoltaic applications with UV-resistant, double-insulated construction.

What does 1500 V DC mean on a PV cable?

It is the maximum direct-current voltage the cable insulation is rated to withstand. Modern utility-scale strings can reach 1500 V DC, so the cable must be rated at least that high for safety and compliance.

How long does photovoltaic cable last outdoors?

A properly specified, UV- and ozone-resistant PV cable is designed for a service life matching the 25–30 year lifespan of a solar module, assuming correct installation and no mechanical damage.

Sources & attributed quotations

“Photovoltaic (PV) systems are exposed to high temperatures and UV radiation; the cables must be resistant to these conditions over the system lifetime.”

— International Electrotechnical Commission, IEC 62930 — Cables for photovoltaic systems · official source

More from the blog

Need help specifying the right cable?

Send us your voltage, temperature and application requirements — our engineers will confirm the construction and send a datasheet.