Technical Blog

Marine Cable Applications: How Do You Choose Shipboard Power, Control and Communication Cables?

Marine cable applications: fixed shipboard power, control and communication circuits up to 18/30(36) kV under IEC 60092, EPR and XLPE insulation, branch cable vs traditional cable busway, and low-smoke halogen-free material choices.

9 min readLIAONING CHUANGSHENG

Marine cable applications split into fixed shipboard systems and equipment that flex. For fixed power, control and instrumentation circuits, select copper conductors with EPR or XLPE insulation and a sheath matched to the vessel zone; IEC 60092-350:2020 covers systems up to 18/30(36) kV. Use separately specified flexible cables for cranes, thrusters and moving decks, and confirm low-smoke halogen-free requirements against the vessel's fire rules before ordering.

Start with the circuit, the zone and the applicable standard

A marine cable application is not defined by the word "marine" on a datasheet. Split the installation into fixed systems and equipment that flexes. IEC 60092-350:2020 states that its constructional requirements and test methods cover copper-conductor power, control and instrumentation cables for fixed electrical systems up to 18/30(36) kV on ships and offshore units; IEC 60092-352:2025 addresses selection and installation for the same voltage range. Our marine cable family covers CEF / CEFR EPR-insulated power cables, CVV / CYJV XLPE-insulated power cables and EPR-insulated communication cables. Rated voltage, core count and cross-section are confirmed to the vessel specification, not assumed from a model name.

Fixed does not mean motionless: IEC 60092-352 explicitly includes systems exposed to ship vibration and movement. Identify the route — engine room, exposed deck, accommodation or an offshore module — and the mechanical risks along it. Our shipboard power types use tinned copper conductors with EPR or XLPE insulation and a sheath to classification requirements. EPR and XLPE are different insulation systems, so the choice follows the specified voltage, thermal class and flexibility, not preference alone. Ask the yard and class surveyor which construction, sheath compound and fire performance the vessel requires; we manufacture to the confirmed specification and do not infer any approval from a product name.

Control and communication circuits need their own line items. The EPR-insulated marine communication cable in our range uses a copper conductor, EPR insulation and a sheath and screen to specification, with listed applications in shipboard communication, navigation systems and offshore platforms. For instrumentation and control circuits, define core count, cross-section and screening before requesting a quote, and keep signal routes separate from high-current power routes where the system design requires it. A cable that is right for a main feeder is not automatically right for a navigation or control loop.

Branch cable vs traditional cable busway in ship distribution

When a yard compares a branch cable vs traditional cable busway for low-voltage distribution, the decision is about topology rather than a catalogue model. A branch cable system uses a main feeder with factory-prefabricated branch joints, so tap-offs are prepared before installation. Our YFD / FZ 0.6/1 kV plastic-insulated branch cable (FDVV, FDYJV) is built around a main cable and a prefabricated branch joint; its published applications are vertical risers, high-rise buildings and commercial complexes. A traditional busway uses rigid busduct sections with tap-off boxes for high-current distribution.

On a vessel, weight, route length, vibration, washdown and access dominate the comparison. Prefabricated branch joints reduce field jointing and make repeated small tap-offs predictable; a busway can simplify very high-current runs and later reconfiguration, but it needs space, supports and protection from vibration and moisture. Neither option is automatically compliant on board. The branch cable line above is published for building distribution and is not presented as a certified marine product: before specifying it for a ship, confirm insulation, sheath, flame performance and classification acceptance against IEC 60092-352 and the vessel's rules.

A useful enquiry states the rated voltage (for our branch cable, 0.6/1 kV), main cable cross-section, the number and position of branch joints, each branch cross-section, PVC or XLPE insulation, sheath type and whether the route crosses fire zones. Ask the designer to verify short-circuit withstand at every tap, segregation of circuits and class acceptance. We confirm model, voltage and construction before order and do not publish approvals or ratings we cannot evidence.

Low-smoke halogen-free materials and cables that really move

For routes through enclosed passenger or accommodation spaces, specifiers often request an eco friendly power cable low smoke halogen free construction. In our range, the environmentally friendly power cable uses a copper or aluminium conductor with LSZH insulation and LSZH sheath; its published applications are public buildings, metros and tunnels, which is not a blanket marine approval. On a ship or offshore unit, reduced smoke and halogen-free compounds must be tied to the flame, smoke and toxicity requirements of the vessel specification and class rules. Confirm the exact test standard and report before writing "LSZH" into a shipboard schedule.

IEC 60092-352:2025 also draws a line for moving equipment: flexible cables are frequently used for retractable thrusters, elevators, moving decks, cranes and shore connections, while cables intended for frequent or continual flexing are detailed in other specifications such as IEC 60227 and IEC 60245. Choose a construction rated for that mechanical duty instead of adapting a fixed-installation shipboard cable. Where a run repeatedly bends in a carrier, a drag-chain style specialty cable may be discussed, but its use in an exposed marine environment needs explicit confirmation; we do not claim marine approval for such a construction.

The final checklist is simple: list every circuit with voltage, core count, cross-section, fixed or moving duty, zone, fire performance and class requirement; keep power, control and communication separate where the design calls for it; verify minimum bend radius, supports, glands and penetration seals; then request a quotation with the confirmed construction and test basis. Send the vessel or offshore specification to info@chuangshengcable.com or WhatsApp +86 17112662227 and we will confirm what can be manufactured. No price, certificate number or capacity figure is published here because those depend on the confirmed project documents.

Frequently asked questions

What voltage range do IEC 60092 shipboard cable rules cover?

IEC 60092-350:2020 covers copper-conductor power, control and instrumentation cables for fixed systems at voltages up to and including 18/30(36) kV on ships and offshore units. IEC 60092-352:2025 uses the same 18/30 (36) kV upper range for selection, installation and operating conditions. Our marine power cable family is confirmed to the vessel specification, including 0.6/1 kV type assignments where specified.

How do I choose between EPR and XLPE insulated marine power cables?

Both are published in our marine range: CEF / CEFR with EPR insulation and tinned copper conductors, and CVV / CYJV with XLPE insulation. Select by the specified voltage, insulation system, flexibility and classification requirement, then fix the core count and cross-section. Model, voltage, sheath and construction are confirmed before order rather than taken from a generic description.

Is a branch cable system suitable for a ship?

It can be evaluated, but not assumed. Our YFD / FZ branch cable is a 0.6/1 kV plastic-insulated product with prefabricated branch joints, published for vertical risers and building distribution. For shipboard use, the yard must confirm it against IEC 60092-352 and class rules for insulation, sheath, flame performance and installation. We do not present it as a certified marine cable.

When is a low-smoke halogen-free power cable needed on board?

An eco friendly power cable low smoke halogen free construction is frequently specified where cable routes pass enclosed passenger or accommodation spaces and where smoke and halogen exposure are concerns. Our eco-friendly power cable uses a copper or aluminium conductor with LSZH insulation and LSZH sheath, published for public buildings, metros and tunnels. For a vessel, tie the material choice to the project's flame, smoke and toxicity tests and obtain the relevant report; the material name alone is not an approval.

Sources & attributed quotations

“IEC 60092-350:2020 provides the general constructional requirements and test methods for use in the manufacture of electric power, control and instrumentation cables with copper conductors intended for fixed electrical systems at voltages up to and including 18/30(36) kV on board ships and offshore (mobile and fixed) units.”

— International Electrotechnical Commission, IEC 60092-350:2020 — Electrical installations in ships - Part 350: General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications · official source

“The reference to fixed systems includes those that are subjected to vibration (due to the movement of the ship) or movement (due to motion of the ship) and not to those that are intended for frequent flexing.”

— International Electrotechnical Commission, IEC 60092-352:2025 — Electrical installations in ships - Part 352: Selection, installation, and operating conditions of cables · official source

More from the blog

Need help specifying the right cable?

Send us your voltage, temperature and application requirements — our engineers will confirm the construction and send a datasheet.

Explore more